Summary of Laing DDC pumps
The article presents all available technical specifications of Laing DDC pumps
Laing DDC pump specification spreadsheet
Laing DDC 1 (DDC 3.1) | Laing DDC 1Plus (DDC 3.2) | Laing DDC 3.15 | Laing DDC 3.25 | |
---|---|---|---|---|
Documents: | Datasheet | Datasheet | ||
Manual | Manual | |||
Performance, l/h: | 420 | 500 | 300 | 522 |
Max Head, Hmax, m: | 3.7 | 4.7 | 4.2 | 4.9 |
Noise level, dBa: | 24 ~ 26 | 30 ~ 32 | 24 ~ 26 | ~ 31 |
Inlet: | hose barb 3/8″ (9.5mm) or G1/4 thread | |||
Outlet: | hose barb 3/8″ (9.5mm) or G1/4 thread | |||
Rated voltage: | 8-13.2 Volt DC (minimum start-up Voltage 9V) | |||
Power consumption, W: | 10 | 18 | 13 | 18 |
Maximum Working Pressure: | 150 kPa (1.5 bar) / 21.75 PSI | |||
Max. Temperature: | 60° C / 140° F | |||
Dimensions — in brackets with G1/4 male connection (H x L x W), mm: | 38(40) x 62(62) x 62(62) | |||
Materials of Construction: | Pump Housing — Nylon/PPO “O” Ring — EPDM or Viton Impeller — Nylon/PPO Bearing — Carbon/Allumina Ceramic All Other Wetted Parts — 316 Stainless Steel or Plastic | |||
Wetted Parts: | Stainless steel 1.4571, PPS-GF40, EPDM gasket, Aluminium oxide, carbon; PA6.6 GF35 | |||
Acceptable media: | water, Water-/Glycolc Mixtures, other medias on request (check pump performance for mixtures of 20% or more glycole) | |||
Features: | Automatic Overload Protection. The tach signal is an open collector type max 20mA, max 24v, 2 pulses per revolution | |||
Notes: | ||||
Price: |
No comments